Tech guide · how to size a pure sine inverter

Sizing a pure sine inverter and battery bank

An inverter converts DC from a battery bank into household AC. Sizing it is two questions: what is the worst-case surge, and how much energy do you need between recharges? Get both wrong and the inverter shuts down the first time a refrigerator starts.

By the ChargingChargers tech bench · Reviewed 2026-10-19 · 4 sections

Pure sine vs modified sine

A modified sine inverter approximates household AC with a stepped waveform. It works for simple resistive loads and it is cheap. Pure sine produces a clean waveform — often cleaner than the grid — so motors run cooler and electronics behave.

We only sell pure sine. The devices that misbehave on modified sine include laser printers and copiers, clock radios that lose time, variable-speed sewing machines, transformerless chargers, dimmers, furnace controls and HID lighting. For audio and video work, pure sine is not optional.

Continuous vs surge watts

Inverters carry two ratings: continuous (runs all day) and surge (seconds). Motors can pull 3–4× their running load at startup. Size to the sum of running watts plus the largest single surge — not the sum of every surge at once, which almost never happens.

LoadSurge factor
Refrigerator / freezer5×
Air compressor4×
Dishwasher3×
Automatic washer3×
Sump pump3×
Furnace fan3×
Industrial motors3×
Circular saw3×
Kerosene / diesel heater2×

Watts to amps: sizing the bank

Two formulas cover almost every DC calculation you will do:

V × A = W  ·  W ÷ V = A

Inverters are 80–90% efficient, so add 10–20% to the DC side. A shortcut that folds this in: divide AC watts by 10 to get DC amps on a 12 volt system.

Example. 500 W AC load for 4 hours a day. 500 ÷ 10 = 50 DC amps. 50 A × 4 h = 200 Ah discharged. At a 50% depth of discharge you need a 400 Ah bank; for longer life, at 25% DoD, an 800 Ah bank (and in practice a little more than either, because capacity falls at high discharge rates).

Typical battery sizes

BCI groupVoltageCapacity
GC2 (golf cart)6 V220 Ah
3112 V105 Ah
4D12 V200 Ah
8D12 V245 Ah

In vehicles, run the inverter from dedicated deep-cycle batteries, not the starting battery. Charge both sets through a battery isolator so the inverter can never strand you.

Parts mentioned in this guide

Common questions

Can I run a microwave on a 1000 W inverter?

Usually not. A 1000 W microwave draws more than its cooking rating, and startup surge pushes it higher. Size for the nameplate watts plus surge, then add inverter inefficiency.

Do I need pure sine for a laptop or phone charger?

No, but small switching supplies are exactly the loads that run hot or buzz on modified sine. Pure sine is the safer long-term choice and costs little at small wattages.

Will an inverter drain my battery when nothing is on?

Idle draw is real — typically a few watts. For long unattended periods use the inverter's remote switch or a transfer-switch model that shuts down cleanly.